Electro-static dust(tar) remover
Technology introduction: electric field can be set up when high voltage direct current is applied between two electrodes, then corona discharge occurs between two electrodes. Dust and tar particles move towards counter electrode under coulomb force when gas passes through this field, and they are captured by the counter electrode. Therefore electro-static dust(tar) remover has the advantages of high efficiency, low resistance drop and low power consumption.
Technology introduction: electric field can be set up when high voltage direct current is applied between two electrodes, then corona discharge occurs between two electrodes. Dust and tar particles move towards counter electrode under coulomb force when gas passes through this field, and they are captured by the counter electrode. Therefore electro-static dust(tar) remover has the advantages of high efficiency, low resistance drop and low power consumption.
Performance parameter:
Designation
|
Unit |
Performance parameters |
|||||||
Model |
C-9 |
C-16 |
C-24 |
C-39 |
C-45 |
C-48 |
C-72 |
C-97 |
|
Pieces of ionizing plate |
pc |
9 |
16 |
24 |
39 |
45 |
48 |
72 |
97 |
Effective sectional area |
m2 |
0.44 |
0.9 |
1.34 |
2.2 |
2.5 |
2.69 |
3.37 |
5 |
Treating capacity |
Nm3/h |
600-900 |
1350-2000 |
2400-3000 |
4000-6500 |
5500-6500 |
5000-7000 |
6400-10000 |
8900-11200 |
Pipe diameter of precipitating electrode(inside diameter) |
mm |
Φ250 |
Φ250 |
Φ250 |
Φ250 |
Φ250 |
Φ250 |
Φ250 |
Φ250 |
Length of precipitating electrode |
m |
3.5 |
3.5 |
3.5 |
3.5 |
3.5 |
3.5 |
3.5 |
3.5 |
Working voltage |
kv |
40-50 |
40-50 |
40-50 |
40-50 |
40-50 |
40-50 |
40-50 |
40-50 |
Working voltage |
ma |
30-50 |
30-50 |
40-60 |
70-100 |
80-110 |
90-110 |
120-160 |
120-160 |
Total weight of equipment |
t |
3 |
6 |
9.5 |
12 |
14 |
15 |
18 |
19 |
Working media |
|
Water gas, semi-water gas, producer gas, exhaust gas |
Add:South of the Airport Road overpass, West Outer Ring Road, Lubei District, Tangshan